The hose kits shown on previous pages use various balancing methods, yet all kits have common features which most designers and owners feel offer them good value. The following hoses and accessories are used on the AutoFlow Kit A,and FlowSet Kit B and Kit C.

Model S2 / S3 Hoses

S2/S3 Hose Assembly

The fire-rated hose assembly has a braided stainless steel outer band with EPDM inner tube and brass or steel fittings. Hose is tested to 450 PSI and covered by an exclusive 12-month hose and labor warranty. Notes: 1/2"-1" hoses use brass fittings; 1 1/4"-2" hoses use steel fittings.

Submittal F275 Installation Specifications

Condensate Hoses

Clear Vinyl Condensate Hose

Clear Vinyl Condensate Hose, 3/4" I.D. with appropriate M.P.T. sized nylon fittings. To be used when 2" differential "P" trap is required.

Submittal F Installation Specifications

Clear Vinyl Condensate Hose

Clear Vinyl Condensate Hose, 3/4" I.D. with appropriate M.P.T. sized nylon fittings. To be used when 2" differential "P" trap is required and connected to ball type blowdown valve.

Submittal F Installation Specifications

Accessories

Pressure/Temperature Test Ports

with Superseal P/T plug features dual durometer EDPM (Nordel) internal seals and dual seal safety cap, with retaining strap. Single P/T Port, P/T Port w/ P/T extender, and Dual XL Ports for Kits A & B. Use Pressure/Temp Port in any device with port section. Regular - Hgt. = 1-1/4", Extended - Hgt. = 2-3/4". Rated 1000 psig at 270°F.

Submittal F119 Installation Specifications

Manual Air Vent

has a brass body and a blowout-proof needle style valve with a side vent. The knurled/slotted top can be sealed finger tight. Rated 400 psig at 250°F.
Knurled, slotted handle manual air vent, use with any port section device. Hgt = 1-1/2".

Submittal F201 Installation Specifications

Stem Extender

Use to extend accessories to clear 2" insullation (MPT x FPT 1/4" or 1/8"). Extends access valve, air vent, or blowdown.

Submittal F Installation Specifications

Memory Stop

Use for ball valve devices that do not come standard with memory stop.
Memory Stop for 1/2" - 2" Valves.

Submittal F Installation Specifications

Sweat Adapter (SWT X FPT)

Use in addition to nipples provided with kit for sweat connected units (1/2" - 1").

Note: Must be sweated / soldered separate from hose before connecting. Not doing this voids warranty.

Submittal F Installation Specifications

Hose Size Increaser

Use in addition to nipples provided with kit for one size larger heat pump (1/2" - 1") connection.
Figure A: Hose Size Increaser 1/2" hose to 3/4" connection, 3/4" hose to 1" connection
Figure B: 1" hose to 1 1/4" connection

Submittal F Installation Specifications

Inverted Flare Reducing Nipple

Use in addition to nipples provided with kit for one size smaller heat pump (1/2" - 1") connection.
3/4" hose to 1/2" connection, 1" hose to 3/4" connection

Submittal F Installation Specifications

Sweat Adapter (SWT X MPT)

Use in lieu of nipples provided with kit for sweat connected units (1-1/4" - 2").

Note: Must be sweated / soldered separate from hose before connecting. Not doing this voids warranty.

Submittal F Installation Specifications

Reducing Bushing w/ Nipple

Use in lieu of nipples provided with kit for connections at heat pump (1-1/4" - 2") for one size difference.
(Either one size up or down heat pump connection size.)

Submittal F Installation Specifications

Hose End Drain Valve

Hose End Drain Valve is a brass ball valve with chrome-plated ball, PTFE seats, plastic handle and a 3/4" hose outlet with cap. Rated 400 psig at 250° F.

Submittal F201 Installation Specifications

1/4" Mini-Ball Drain Valve

Mini-Ball Drain Valve has a brass body plastic handle and 1/4" FPT outlet connection. Rated 400 psig at 275°F.

Submittal F201 Installation Specifications

Extended Handle

on ball valve products provides approximately 2" extra clearance for insulation.

Metal ID Tags

Tempered aluminum tag with chrome plated ball chain. Mylar label with etched writable information blocks.